Please use this identifier to cite or link to this item: http://hdl.handle.net/11189/9161
Title: Nanoparticles application in the determination of Uric acid, Ascorbic acid, and Dopamine
Authors: Van der Horst, Charlton 
Somerset, Vernon 
Keywords: Uric acid;ascorbic acid;dopamine;nanoparticles;electrochemical sensors
Issue Date: 2022
Publisher: Pleiades Publishing, Ltd
Source: Van der Horst, C. & Somerset, V. 2022. Nanoparticles application in the determination of Uric acid, Ascorbic acid, and Dopamine. Russian Journal of Electrochemistry, 58(5): 341-359. [https://doi.org/10.1134/S102319352205010X]
Journal: Russian Journal of Electrochemistry 
Abstract: This review describes the application of nanomaterials for the individual and simultaneous detection of dopamine (DA), uric acid (UA), and ascorbic acid (AA). Scientists have worked over the past years to modify electrode surfaces by using different nanomaterials to improve the selectivity, limits of detection, and sensitivity of sensors. In this review, the authors have briefly discussed the nanomaterials that were extensively applied in the construction and modification of working electrode surfaces for the detection of DA, UA, and AA. The electrochemical detection of DA, UA, and AA were categorized into three main sections including the detection in the presence of interferents, individual detection and the simultaneous detection of these molecules. For the individual detection of DA, UA, and AA the lowest detection limit was achieved by a Au/PDDA–rGO sensor in the detection of UA in urine samples. A detection limit of 0.0008 μM with a wide linear range of 0.25 to 150 μM was recorded. In the simultaneous detection of DA, UA, and AA in serum and urine samples, a Fe3O4–SnO2–Gr sensor gives the lowest detection limits (0.0071 μM for DA, 0.005 μM for UA, 0.0062 μM for AA) with good linear range (0.02 to 2.8 μM for DA, 0.015 to 2.40 μM for UA, 0.1 to 23 μM for AA). In the case of the simultaneous detection of DA and UA in serum and urine samples, the lowest detection limits were obtained by Au–Pt sensor. The detection limits (0.006 μM for DA, 0.038 μM for UA) with good linear range (0.1 to 400 μM for DA, 1 to 1000 μM for UA).
URI: http://hdl.handle.net/11189/9161
ISSN: 1023-1935
DOI: https://doi.org/10.1134/S102319352205010X
Appears in Collections:Appsc - Journal Articles (DHET subsidised)

Files in This Item:
File Description SizeFormat 
Nanoparticles_application.pdfArticle1.05 MBAdobe PDFView/Open
Show full item record

Page view(s)

62
Last Week
2
Last month
9
checked on Dec 29, 2025

Download(s)

70
checked on Dec 29, 2025

Google ScholarTM

Check

Altmetric


Items in Digital Knowledge are protected by copyright, with all rights reserved, unless otherwise indicated.