Please use this identifier to cite or link to this item: http://hdl.handle.net/11189/7777
Title: Comparison of the operational speed of hard-wired and IEC 61850 standard-based implementations of a reverse blocking protection scheme
Authors: Mnguni, Mkhululi Elvis Siyanda 
Tzoneva, Raynitchka 
Keywords: Busbar;Power system;Reverse busbar blocking scheme;IEC61850 standard;Distribution systems;Protection relays;IEDs;GOOSE message;Laboratory test bench
Issue Date: 2015
Publisher: The Korean Institute of Electrical Engineers
Source: Mnguni, M.E.S. & Tzoneva, R. 2015. Comparison of the operational speed of hard-wired and IEC 61850 standard-based implementations of a reverse blocking protection scheme. Journal of Electrical Engineering & Technology, 10(3): 740-754. [http://dx.doi.org/10.5370/JEET.2015.10.3.740]
Journal: Journal of Electrical Engineering & Technology 
Abstract: This paper focuses on the reverse blocking busbar protection scheme with aim to improve the speed of its operation and at the same time to increase operational reliability, flexibility and stability of the protection during external and internal faults by implementation of the extended functionality provided by the IEC61850 standard-based protective Intelligent Electronic Devices (IEDs). The practical implementation of the scheme by the use of IEC 61850 standard communication protocol is investigated. The proposed scheme is designed for a radial type of a distribution network and is modeled and simulated in the DigSILENT software environment for various faults on the busbar and its outgoing feeders. A laboratory test bench is built using three ABB IEDs 670 series that are compliant with the IEC 61850 standard, CMC 356 Omicron test injection device, PC, MOXA switch, and a DC power supplier. Two types of the reverse blocking signals between the IEDs in the test bench are considered: hard wired and Ethernet communication by using IEC 61850 standard GOOSE messages. Comparative experimental study of the operational trip response speeds of the two implementations for various traffic conditions of the communication network shows that the performance of the protection scheme for the case of Ethernet IEC 61850 standard-based communication is better.
URI: http://hdl.handle.net/11189/7777
ISSN: 1975-0102
2093-7423
DOI: http://dx.doi.org/10.5370/JEET.2015.10.3.740
Appears in Collections:Eng - Journal articles (DHET subsidised)

Files in This Item:
File Description SizeFormat 
Comparison of the Operational Speed of Hard-wired and IEC 61850.pdf3.58 MBAdobe PDFView/Open
Show full item record

Google ScholarTM

Check

Altmetric


Items in Digital Knowledge are protected by copyright, with all rights reserved, unless otherwise indicated.