Please use this identifier to cite or link to this item: http://hdl.handle.net/11189/7318
DC FieldValueLanguage
dc.contributor.authorParbhunath, Olivia L.en_US
dc.contributor.authorRautenbach, Fanieen_US
dc.contributor.authorDavison, Glenda Maryen_US
dc.contributor.authorMarnewick, Jeanine Len_US
dc.date.accessioned2020-06-19T09:25:58Z-
dc.date.available2020-06-19T09:25:58Z-
dc.date.issued2014-
dc.identifier.citationParbhunath, O. L., Rautenbach, F., Davison, G. et al. 2014. Optimization and Validation of a Reverse-Phase High Performance Liquid Chromatography Assay with Ultra-Violet Detection for Measuring Total L-Ascorbic Acid in Food and Beverage Products. Journal of analytical and bioanalytical techniques, 5(4): 201. [http://doi.org/10.4172/2155-9872.1000201]en_US
dc.identifier.issn2155-9872-
dc.identifier.urihttp://hdl.handle.net/11189/7318-
dc.description.abstractIn accordance with national and international regulatory standards, namely ISO/IEC 17025, the validation of chromatography methods is becoming necessary. This study provides an optimized and fully validated reverse- phase high performance liquid chromatography (RP-HPLC) assay with ultra-violet (UV) detection for the measure- ment of L-ascorbic acid (L-AA) in fruit, vegetable and food products. Several commercial fruit juices and teas, fresh fruit and vegetables and food extract products were analyzed us- ing a high performance liquid chromatographic system with UV detection. Chromatographic separation of L-AA was achieved on a reverse phase C 150 mm×4.6 mm, 0.5 µm column with UV detection of 245 nm at room temperature. Distilled water/acetonitrile/formic acid (99: 0.9: 0.1, v/v/v) at a flow rate of 1 mLmin-1 was used as the mobile phase, in isocratic mode. Samples were extracted in 4.5% metaphosphoric acid solution and filtered through a 0.45 µm membrane. The method was validated for accuracy, precision, linearity, range, limit of detection, limit of quantifica- tion, specificity, stability, robustness and system suitability in accordance with ISO 17025 validation requirements. Validation results demonstrated a linear response within a range of 5 to 125 µg/mL with a correlation coefficient of 0.999 was obtained. Mean recoveries ranged from 99 to 103% and 92 to 96% for L-AA standards and samples, respectively. The method was found to be precise (COV’s <5%) and specific with no interferences from coexisting peaks. The LOD and LOQ were 0.61 µg/mL and 1.84 µg/mL respectively. The successful optimization and validation of the proposed method should make it easily applicable for routine laboratory analysis of L-AA measurement in various fruit and vegetable products.en_US
dc.language.isoenen_US
dc.publisherOMICS Internationalen_US
dc.relation.ispartofJournal of analytical and bioanalytical techniquesen_US
dc.subjectValidationen_US
dc.subjectL-ascorbic aciden_US
dc.subjectHigh performance liquid chromatographyen_US
dc.subjectInternational Organization for Standards (ISO 17025)en_US
dc.titleOptimization and Validation of a Reverse-Phase High Performance Liquid Chromatography Assay with Ultra-Violet Detection for Measuring Total L-Ascorbic Acid in Food and Beverage Productsen_US
dc.identifier.doihttp://doi.org/10.4172/2155-9872.1000201-
dc.typeArticleen_US
Appears in Collections:HWSci - Journal Articles (DHET subsidised)
Files in This Item:
File Description SizeFormat 
Optimization and Validation of a Reverse.pdf848.97 kBAdobe PDFView/Open
Show simple item record

Page view(s)

239
Last Week
0
Last month
29
checked on Aug 19, 2026

Download(s)

117
checked on Aug 19, 2026

Google ScholarTM

Check

Altmetric


Items in Digital Knowledge are protected by copyright, with all rights reserved, unless otherwise indicated.