| dc.identifier.citation | Mditshwa, M., Mnguni, M.E.S. & Ratshitanga, M. 2022. The limitations of an automatic generation control in stabilizing power system in the event of load demand increase. 30th Southern African Universities Power Engineering Conference (SAUPEC), Durban, South Africa, 25-27 January. [https://ieeexplore.ieee.org/document/9730750] | en_US |
| dc.identifier.isbn | 9781665468879/22 | - |
| dc.identifier.uri | https://ieeexplore.ieee.org/document/9730750 | - |
| dc.identifier.uri | http://hdl.handle.net/11189/9506 | - |
| dc.description.abstract | The main objective of an Automatic Generation Control (AGC) is to maintain the power system frequency to its nominal value following a disturbance. However, the control action of the AGC is dependable on the availability of spinning reserves. Due to deficiency generation reserve capacity, the system frequency stability can be compromised. The benefits and limitations of an automatic generation control are outlined in this paper. The AGC was developed and implemented on a modified IEEE 14 bus power system network using the DIgSILENT PowerFactory simulation tool. The results indicate that the AGC is only effective in the power system when there are enough spinning reserves. When the generation spinning reserves are depleted, the system frequency can not be maintained at its nominal state following load demand increase. | en_US |
| dc.language.iso | en | en_US |
| dc.publisher | IEEE Xplore | en_US |
| dc.relation.ispartof | 30th Southern African Universities Power Engineering Conference (SAUPEC) | en_US |
| dc.subject | Frequency control | en_US |
| dc.subject | power system stability | en_US |
| dc.subject | spinning reserves | en_US |
| dc.subject | automatic Generation Control | en_US |
| dc.subject | governing system | en_US |
| dc.title | The limitations of an automatic generation control in stabilizing power system in the event of load demand increase | en_US |
| dc.type | Article | en_US |
| Appears in Collections: | Eng - Conference Proceedings | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| Limitations_of_an_Automatic_Generation.pdf | 574.36 kB | Adobe PDF | View/Open |
Page view(s)
194
Last Week
0
0
Last month
6
6
checked on Sep 2, 2026
Download(s)
103
checked on Sep 2, 2026
Google ScholarTM
Check
Items in Digital Knowledge are protected by copyright, with all rights reserved, unless otherwise indicated.