Please use this identifier to cite or link to this item: http://hdl.handle.net/11189/8851
Title: Conventional testing produces submaximal values for oxygen uptake in elite runners
Authors: Beltrami, Fernando G. 
Noakes, Timothy David 
Keywords: Plateau;elite athletes;VO˙ 2max;running
Issue Date: 2021
Publisher: Human Kinetics, Inc.
Source: Beltrami, F. G. & Noakes, T. D. 2021. Conventional testing produces submaximal values for oxygen uptake in elite runners. International Journal of Sports Physiology and Performance, 16(10): 1510-1515. [https://doi.org/10.1123/ijspp.2020-0778]
Journal: International Journal of Sports Physiology and Performance 
Abstract: Purpose: This study aimecd to investigate whether elite athletes could reach higher values of maximal oxygen uptake (VO˙ 2max) during a decremental exercise test in comparison with a traditional incremental test, as recently demonstrated in trained individuals. Methods: Nine male runners (age 25.8 [5.1] y, season best 10-km time 31:19 [1:50]) performed, on different days, 3 maximal uphill (5% grade) running exercise tests in fixed order: an incremental test (INC1), a V-shape exercise test (where speed started at 0.5 km·h−1 higher than the top stage finished during INC1 and was slowly decreased during 5.5 min, when it was again increased in similar fashion to the INC tests), and a final incremental test (INC2). Results: VO˙ 2max during the V-shape exercise test was higher than during INC1 (6.3% [3.0%], P = .01), although running speed was lower (16.6 [1.7] vs 17.9 [1.6] km·h−1 , P = .01). Performance was similar between INC1 and INC2, but VO˙ 2max during INC2 was higher than INC1 (P < .001). During the V-shape exercise test, 5 participants reached the incremental part of the test, but VO˙ 2 did not increase (ΔVO˙ 2 = 52 ½259 mL · min−1, P = .67), despite higher running speed (approximately 1.1 km·h−1 , P < .01). Heart rate, pulmonary ventilation, breathing rate, and respiratory exchange ratio measured at VO˙ 2max were not different between tests. Conclusion: A decremental exercise test of sufficient intensity can produce higher VO˙ 2max than a traditional incremental test, even in elite athletes, and this is maintained during a subsequent incremental test.
URI: http://hdl.handle.net/11189/8851
ISSN: 1555-0265
1555-0273
DOI: https://doi.org/10.1123/ijspp.2020-0778
Appears in Collections:FID - Journal Articles (DHET subsidised)

Files in This Item:
File Description SizeFormat 
Conventional_testing_produces.pdfArticle359.14 kBAdobe PDFView/Open
Show full item record

Page view(s)

105
Last Week
0
Last month
2
checked on Aug 13, 2026

Download(s)

116
checked on Aug 13, 2026

Google ScholarTM

Check

Altmetric


Items in Digital Knowledge are protected by copyright, with all rights reserved, unless otherwise indicated.