dc.description.abstractThe performance of a wall mounted space comfort heater has been studied with respect to the geometry of its mounting condition. Tests were conducted in a laboratory with the heater positioned at various heights from the floor and the channel that is created by the various gaps with the wall on which the heater was mounted. Tests were also performed with the heater mounted on the wall whose emissivity was adjusted to low, medium and high values as well as placing insulation material on the wall directly behind the heater. The experiments revealed an acceptable geometry of the heater's mounting at least 200mm above the floor, and 50 mm off-set from the wall. The heater's mounting against the wall caused a drop in performance of about 15% of it's maximum “benchmark” performance (with an efficiency of about 41%) achieved when the heater was freely standing on the floor of the laboratory. This efficiency, based on the convective heat transfer generated by the heater's warm/hot surfaces, is relative to the electrical energy input. The heat transfer by radiation from the heater's surface is treated as net loss to the walls of the room/enclosure. The performance of the heater when mounted against the wall improved almost to the benchmark value when the wall behind the heater was made refelective (low emissivity).en_US
dc.language.isoenen_US
dc.publisherCape Peninsula University of Technologyen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/za/-
dc.subjectCalorimetric measurementsen_US
dc.subjectHeat transfer modesen_US
dc.subjectNatural Convectionen_US
dc.subjectNet Radiationen_US
dc.subjectGrashofen_US
dc.subjectNusselt and Prandtl numbersen_US
dc.titleOptimizing the performance of the domestic wall mounted space comfort heateren_US
dc.type.patentOtheren_US
Appears in Collections:Eng - Conference Proceedings
Files in This Item:
File Description SizeFormat 
Tangkeh_J_Gryzagoridis, J_Optimizing the Performance of the Domestic Wall_pdfConference proceedings8.37 MBAdobe PDFView/Open
Show simple item record

Page view(s)

91
Last Week
0
Last month
1
checked on Aug 15, 2026

Download(s)

79
checked on Aug 15, 2026

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons